Zirconia All-ceramic Fixed Partial Dentures

All-ceramic fixed partial dentures have been increasing interest due to demand for esthetic and metal-free restorations of the patients. Yttrium tetragonal zirconia polycrystals has the highest mechanical properties, and promising long term clinical performance. Marginal fit of zirconia fixed partial dentures machined by CAD/CAM systems are lower than metalceramic fixed partial dentures but within the range of clinical acceptability. The 1-5 year success rates of frameworks in most studies were 100% and survival rates were 73.9-100%. The most common complications of zirconia fixed partial dentures were chipping of porcelain veneer. Recent studies indicate that with proper patient selection, 3-4 unit zirconia fixed partial dentures are suitable for replacement of anterior and posterior teeth.

1. Christensen GJ. Choosing an all-ceramic restorative material: porcelain-fused-to-metal or zirconia-based? J Am Dent Assoc 2007; 138: 662-665.

2. Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses. Clin Oral Implants Res 2007; 18 Suppl 3: 86-96.

3. Raigrodski AJ, Chiche GJ. The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature. J Prosthet Dent. 2001 Nov;86(5):520-5.

4. Sadowsky SJ. An overview of treatment considerations for esthetic restorations: a review of the literature. J Prosthet Dent. 2006 Dec;96(6):433-42.

5. Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent. 2004 Dec;92(6):557-62.

6. Raigrodski AJ. All-ceramic full-coverage restorations: concepts and guidelines for material selection. Pract Proced Aesthet Dent. 2005 May;17(4):249-56.

7. Raigrodski AJ. Materials for all-ceramic restorations. J Esthet Restor Dent. 2006;18 (3):117-8.

8. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based threeunit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001 May-Jun;14(3):231-8.

9. Vult von Steyern P, Carlson P, Nilner K. Allceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2- year clinical study. J Oral Rehabil. 2005 Mar; 32(3):180-7.

10. Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, et al. The efficacy of posterior three-unit zirconiumoxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent. 2006 Oct;96(4):237-44.

11. Raigrodski AJ, Saltzer AM. Clinical considerations in case selection for all-ceramic fixed partial dentures. Pract Proced Aesthet Dent. 2002 Jun-Jul;14(5):411-9.

12. Giordano R, 2nd. A comparison of all-ceramic restorative systems: Part 2. Gen Dent. 2000 Jan-Feb;48(1):38-40.

13. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J. 2008 May 10;204(9):505-11.

14. Raigrodski AJ. Contemporary all-ceramic fixed partial dentures: a review. Dent Clin North Am. 2004 Apr;48(2):viii, 531-44.

15. Pilathadka S, Vahalova D, Vosahlo T. The Zirconia: a new dental ceramic material. An overview. Prague Med Rep. 2007;108(1):5-12.

16. Larsson C, Holm L, Lovgren N, Kokubo Y, Vult von Steyern P. Fracture strength of fourunit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study. J Oral Rehabil. 2007 Sep;34(9):702-9.

17. McLaren EA, White SN. Glass-infiltrated zirconia/alumina-based ceramic for crowns and fixed partial dentures. Pract Periodontics Aesthet Dent. 1999 Oct;11(8):985-94.

18. Pilathadka S, Vahalova D. Contemporary allceramic materials, part-1. Acta Medica (Hradec Kralove). 2007;50(2):101-4.

19. Davenport M. Predictable esthetic results from the placement of an anterior 3-unit, allceramic CAD/CAM restoration. Synergy in Dentistry. 2005;26(1):3-8.

20. Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent. 2001 JulAug;26(4):367-74.

21. Bindl A, Mormann WH. Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent. 2007 Dec;27(6):567-75.

22. Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater. 2009 Jan;25(1):94-102.

23. Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci. 2005 Apr;113(2):174-9.

24. Vigolo P, Fonzi F. An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont. 2008 Dec;17(8):621-6.

25. Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig. 2008 Sep 4.

26. Gonzalo E, Suarez MJ, Serrano B, Lozano JF. Marginal fit of Zirconia posterior fixed partial dentures. Int J Prosthodont. 2008 Sep-Oct; 21(5):398-9.

27. Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont. 2008 May-Jun;21(3):217-22.

28. Molin MK, Karlsson SL. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont. 2008 May-Jun;21(3):223-7.

29. Crisp RJ, Cowan AJ, Lamb J, Thompson O, Tulloch N, Burke FJ. A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results. Br Dent J. 2008 Nov 8;205(9):477-82.

30. Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007 Jul-Aug; 20(4):383-8.

31. Sailer I, Feher A, Filser F, Luthy H, Gauckler LJ, Scharer P, et al. Prospective clinical study of zirconia posterior fixed partial dentures: 3- year follow-up. Quintessence Int. 2006 Oct; 37(9):685-93.

32. Taskonak B, Sertgoz A. Two-year clinical evaluation of lithia-disilicate-based allceramic crowns and fixed partial dentures. Dent Mater. 2006 Nov;22(11):1008-13.

33. Vult von Steyern P, Jonsson O, Nilner K. Fiveyear evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont. 2001 Jul-Aug;14(4):379-84.

34. Suarez MJ, Lozano JF, Paz Salido M, Martinez F. Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs. Int J Prosthodont. 2004 Jan-Feb;17(1):35-8.

35. Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications in fixed prosthodontics. J Prosthet Dent. 2003 Jul; 90(1):31-41.

Puriwarangkakul V, Adchariyapitak N. Zirconia All-ceramic Fixed Partial Dentures: Review articles. CM Dent J [Internet]. 2024 Dec 06 [cited 2025 May 03];31(1):47-55. Available from: https://www.dent.cmu.ac.th/cmdj/frontend/web/?r=site/viewarticle&id=378

Puriwarangkakul, V. & Adchariyapitak, N. (2024). Zirconia All-ceramic Fixed Partial Dentures. CM Dent J, 31(1), 47-55. Retrieved from: https://www.dent.cmu.ac.th/cmdj/frontend/web/?r=site/viewarticle&id=378

Puriwarangkakul, V., and Napaporn Adchariyapitak. 2024. "Zirconia All-ceramic Fixed Partial Dentures." CM Dent J, 31(1), 47-55. https://www.dent.cmu.ac.th/cmdj/frontend/web/?r=site/viewarticle&id=378

Puriwarangkakul, V. et al. 2024. 'Zirconia All-ceramic Fixed Partial Dentures', CM Dent J, 31(1), 47-55. Retrieved from https://www.dent.cmu.ac.th/cmdj/frontend/web/?r=site/viewarticle&id=378

Puriwarangkakul, V. and Adchariyapitak, N. "Zirconia All-ceramic Fixed Partial Dentures", CM Dent J, vol.31, no. 1, pp. 47-55, Dec. 2024.

Varaporn Puriwarangkakul, Napaporn Adchariyapitak "Zirconia All-ceramic Fixed Partial Dentures." CM Dent J, vol.31, no. 1, Dec. 2024, pp. 47-55, https://www.dent.cmu.ac.th/cmdj/frontend/web/?r=site/viewarticle&id=378